SKH086EEP - Flame Sensor for Belt Conveyors

  • Applied vibration-resistant, heat-resistant, dustproof, and waterproof technologies from heavy machinery flame sensors to develop a flame sensor for belt conveyors.

  • Compact and simple design allows direct installation inside belt conveyors or pits, enabling effective monitoring of high-risk areas where conventional sensors are difficult to install.

Proprietary UV Separation Technology
Uses unique technology to separate ultraviolet (UV) rays from sunlight and flames, allowing outdoor use without false alarms caused by sunlight.

High-Sensitivity & Fast Flame Detection with UV Technology
Detects a small flame (approximately 2 cm high, like a lighter flame) from 5 m away.
Detects a 1 m-high flame from approximately 35 m away.
Fastest detection time: 0.5 seconds.

Suitable for Harsh Environments
Equipped with vibration resistance, heat resistance, dustproof, and fully waterproof capabilities, making it suitable for various environments.

Adjustable Mounting Angle
Bolts on both sides of the housing allow for flexible angle adjustment, making installation possible even inside narrow spaces of belt conveyors.

Built-in Reverse Polarity Protection Circuit
Equipped with a reverse polarity protection circuit, ensuring operation even if the power polarity is connected incorrectly.

Simple Wiring & Signal Output
Operates by simply connecting two power wires.
Signal output is provided via wired open-collector output.

Product Specifications
Product Name Flame Sensor for Belt Conveyors
Model SKH086EEP
Input Voltage DC 12–24V (Built-in reverse connection protection circuit)
Wiring 6 wires (2 power wires, 2 output wires, 2 detection timer setting wires)
Power Consumption Standby: ≤20mA / Detection: ≤50mA (at 12V DC, room temperature)
Operating Temperature -10℃ to 100℃ (Maximum rating: 115℃)
Detection Method Ultraviolet (UV) detection (Detection wavelength: 185nm–260nm)
Detection Distance Detects a 2cm flame at 5m distance
Detection Angle 90° left/right, 30° up/down (±45° left/right, ±15° up/down from sensor front)
Detection Timer Function Selectable: 0.5s, 4s, 8s, 12s (Configurable via wiring)
Flame Detection Output Open collector output
Alarm Output Hold Function Output hold time: approximately 30s
※ The alarm output turns OFF about 30 seconds after UV detection stops.
Monitoring Location Indoor & Outdoor (Fully waterproof, can be installed on vibrating structures) / Direct installation inside belt conveyors
External Dimensions W53mm × D95mm × H277mm (excluding mounting bolts and protrusions)
Weight Approximately 380g (including standard cable)
Casing Material SUS304 stainless steel